Avaliação do custo energético de diferentes operações agrícolas mecanizadas

dc.contributor.authorFernandes, Haroldo Carlos
dc.contributor.authorSilveira, João Cleber Modernel da
dc.contributor.authorRinaldi, Paula Cristina Natalino
dc.date.accessioned2017-10-19T23:08:58Z
dc.date.available2017-10-19T23:08:58Z
dc.date.issued2007-04-11
dc.description.abstractCom o propósito de aumentar a eficiência de uso de insumos energéticos utilizados na agricultura tropical, procurou-se determinar o custo energético (MJ ha-1) das principais operações agrícolas mecanizadas em quatro sistemas de preparo do solo para a semeadura do milho e quantificar sua possível redução, utilizando os sistemas de preparo conservacionistas, em relação ao sistema convencional. O experimento foi conduzido na Universidade Federal de Viçosa - UFV. O delineamento experimental foi em parcelas subdivididas com quatro tratamentos e nove repetições, totalizando 36 parcelas experimentais. Foram avaliadas a densidade do solo, teor de água do solo e resistência do solo a penetração, o consumo de combustível e o custo energético. O plantio direto foi o sistema que proporcionou menor consumo de combustível, seguido pelo sistema de cultivo mínimo com grade de disco leve, preparo reduzido e preparo convencional, respectivamente. O plantio direto teve um custo energético de 52,72% do custo do sistema convencional e o cultivo mínimo foi de 77,52%, possibilitando economizar entre 1216,51 e 578,39 MJ ha-1, respectivamente, equivalente a 25,45 e 12,10 L de óleo diesel para cada hectare trabalhado.pt-BR
dc.description.abstractThis study was carried out to increase the efficiency of energy inputs used in tropical agriculture, so the energy cost (MJ ha-1) of the main mechanized agricultural operations was determined in four soil preparation systems for seeding of maize. In addition, the possible reduction of this cost by the conservationist preparation systems was quantified, relative to the conventional system. The experiment was conducted in the Universidade Federal de Viçosa- MG, by using the split-plot design with four treatments and nine replicates, total of 36 experimental plots. The following variables were analyzed: soil density, soil water content, soil resistance to penetration, fuel consumption and energy cost. The no-till cropping provided the lowest fuel consumption, followed by the minimum cropping system with light-disk grate, the reduced preparation and the conventional one. The energy cost of the no-till planting was 52.72% the cost of the conventional system, where as the minimum cropping was 77.52%, therefore turning possible to save between 1216.51 and 578.39 MJ ha-1, respectively, which corresponds to 25.45 and 12.10L the diesel oil in each hectare.en
dc.formatpdfpt-BR
dc.identifier.issn1981-1829
dc.identifier.urihttp://dx.doi.org/10.1590/S1413-70542008000500034
dc.identifier.urihttp://www.locus.ufv.br/handle/123456789/12208
dc.language.isoporpt-BR
dc.publisherCiência e Agrotecnologiapt-BR
dc.relation.ispartofseriesv. 32, n. 5, p. 1582-1587, set./out., 2008pt-BR
dc.rightsOpen Accesspt-BR
dc.subjectPlantio diretopt-BR
dc.subjectPreparo do solopt-BR
dc.subjectConsumo de combustívelpt-BR
dc.subjectEnergiapt-BR
dc.titleAvaliação do custo energético de diferentes operações agrícolas mecanizadaspt-BR
dc.typeArtigopt-BR

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
34.pdf
Size:
92.08 KB
Format:
Adobe Portable Document Format
Description:
texto completo

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: