Fast determination of four polar contaminants in soy nutraceutical products by liquid chromatography coupled to tandem mass spectrometry
| dc.contributor.author | Romero-González, Roberto | |
| dc.contributor.author | Alves, Renata Domingos | |
| dc.contributor.author | López-Ruiz, Rosalía | |
| dc.contributor.author | Jiménez-Medina, M. L. | |
| dc.contributor.author | Frenich, Antonia Garrido | |
| dc.date.accessioned | 2018-05-10T16:53:16Z | |
| dc.date.available | 2018-05-10T16:53:16Z | |
| dc.date.issued | 2016-09-05 | |
| dc.description.abstract | An analytical method based on a modified QuPPe (quick polar pesticide) extraction procedure coupled with liquid chromatography-tandem mass spectrometry (LC-MS/MS) was evaluated for the determination of four polar compounds (chlorate, fosetyl-Al, maleic hydrazide, and perchlorate) in nutraceutical products obtained from soy. Experimental con- ditions including extraction such as solvent, acidification, time, and clean-up sorbents were varied. Acidified acetonitrile (1 % formic acid, v/v) was used as extraction solvent instead of methanol (conventional QuPPe), which provides a doughy mixture which cannot be injected into the LC. Clean-up or derivatization steps were avoided. For analysis, several sta- tionary phases were evaluated and Hypercarb (porous graphit- ic carbon) provided the best results. The optimized method was validated and recoveries ranged between 46 and 119 %, and correction factors can be used for quantification purposes bearing in mind that inter-day precision was equal to or lower than 17 %. Limits of quantification (LOQs) ranged from 4 to 100 μg kg^−1. Soy-based nutraceutical products were analyzed and chlorate was detected in five samples at concentrations between 63 and 1642 μg kg^−1. | en |
| dc.format | pt-BR | |
| dc.identifier.issn | 16182650 | |
| dc.identifier.uri | http://dx.doi.org/10.1007/s00216-016-9912-2 | |
| dc.identifier.uri | http://www.locus.ufv.br/handle/123456789/19462 | |
| dc.language.iso | eng | pt-BR |
| dc.publisher | Analytical and Bioanalytical Chemistry | pt-BR |
| dc.relation.ispartofseries | v. 408, n. 28, p. 8089–8098, Novembro 2016 | pt-BR |
| dc.rights | Springer-Verlag Berlin Heidelberg | pt-BR |
| dc.subject | Nutraceuticals | pt-BR |
| dc.subject | Soy | pt-BR |
| dc.subject | Polar compounds | pt-BR |
| dc.subject | QuPPe | pt-BR |
| dc.subject | Liquid chromatography | pt-BR |
| dc.subject | Mass spectrometry | pt-BR |
| dc.title | Fast determination of four polar contaminants in soy nutraceutical products by liquid chromatography coupled to tandem mass spectrometry | en |
| dc.type | Artigo | pt-BR |