Use este identificador para citar ou linkar para este item: https://locus.ufv.br//handle/123456789/20382
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorFiedler, Nilton César
dc.contributor.authorCoelho, Fabrício
dc.contributor.authorMinetti, Luciano José
dc.date.accessioned2018-06-29T11:43:39Z
dc.date.available2018-06-29T11:43:39Z
dc.date.issued2005-05-03
dc.identifier.issn21756813
dc.identifier.urihttps://reveng.ufv.br/index.php/reveng/issue/view/3/showToc
dc.identifier.urihttp://www.locus.ufv.br/handle/123456789/20382
dc.description.abstractEsta pesquisa foi realizada durante as atividades de poda de árvores na arborização urbana no Distrito Federal, durante o período de agosto a dezembro de 2003. Teve como objetivo geral analisar os fatores ergonômicos do ambiente de trabalho, tais como condições climáticas, os níveis de ruído e a iluminação. As condições climáticas foram medidas com o IBUTG. O nível de ruído foi avaliado, utilizando-se um decibelímetro colocado ao nível do ouvido do trabalhador, conforme preceitua a NR 15. A iluminância foi medida com um luxímetro a 0,75 m do solo, conforme a NBR 5413/92. O IBUTG não estava de acordo com a Norma Regulamentadora n° 15, no período das 12 às 15 horas, apresentando o valor máximo de 27°C às 13 horas. Os maiores níveis de ruído foram encontrados nas fases de corte e traçamento com média de 101,5 dB (A). A Iluminância estava de acordo com a NBR 5413/92, que estabelece níveis mínimos entre 200 e 500 LUX. Os níveis variaram de 362 a 969 Lux.pt-BR
dc.description.abstractThis research was done during tree pruning activities in the urban zones of Distrito Federal, Brazil, during August-December 2003, to analyze the ergonomic factors of work environment, especially climatic conditions, illumination and noise level. The climatic conditions were measured with the help of an IBUTG digital thermometer. The noise level was measured with the use of a sound level meter placed at worker’s ear level, according to NR 15. The luminance was evaluated by use of a luximeter placed 0,75m above the ground, in accordance to the NBR 5413/92. The humid bulb index and globe thermometer (IBUTG) did not comply with the regulatory norm 15, from noon to 3p.m., with maximum temperature of 27oC at 1p.m. The highest noise level, averaging 101,5 dB(A), occurred during cutting operations. The light intensity varied between 362 and 969Lux, which is within the NBR 54131/92 that establishes minimum level of 200 to 500Lux.en
dc.formatpdfpt-BR
dc.language.isoporpt-BR
dc.publisherEngenharia na Agriculturapt-BR
dc.relation.ispartofseriesv. 16, n. 2, p. 192-198, abril-junho 2008pt-BR
dc.rightsOpen Accesspt-BR
dc.subjectAvaliação ergonômicapt-BR
dc.subjectFatores ambientais arborização urbanapt-BR
dc.titleAnálise de fatores ergonômicos do ambiente de trabalho nas atividades de poda de árvores no Distrito Federalpt-BR
dc.typeArtigopt-BR
Aparece nas coleções:Artigos

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
artigo.pdfTexto completo1,18 MBAdobe PDFThumbnail
Visualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.