Use este identificador para citar ou linkar para este item:
https://locus.ufv.br//handle/123456789/5712
Tipo: | Dissertação |
Título: | Reutilização de dispositivos intravaginais de progesterona autoclavados para a indução e sincronização de estro em cabras da raça Toggenburg |
Título(s) alternativo(s): | Reutilization of autoclaved intravaginal progesterone device for estrous induction and synchronization in Toggenburg goats |
Autor(es): | Souza, Joanna Maria Gonçalves de |
Primeiro Orientador: | Torres, Ciro Alexandre Alves |
Primeiro coorientador: | Carvalho, Giovanni Ribeiro de |
Segundo coorientador: | Fonseca, Jeferson Ferreira da |
Primeiro avaliador: | Guimarães, José Domingos |
Segundo avaliador: | Espeschit, Claudio José Borela |
Abstract: | O objetivo deste estudo foi avaliar a eficácia da reutilização de
dispositivos intravaginais autoclavados sobre a indução do estro,
ovulação e fertilidade em caprinos da raça Toggenburg, além de
caracterizar o perfil de progesterona plasmática destes animais. O estudo
foi realizado na estação de anestro estacional (n=42) e na estação de
acasalamento natural (n=67), no município de Piau-MG (21°35 S de
latitude e 43°15 W de longitude). As cabras receberam dispositivos
intravaginais de progesterona novos (CN) ou que foram previamente
utilizados por seis (C6) ou 12 dias (C12) e autoclavados posteriormente.
Dinoprost (5 mg) foi administrado latero-vulvar no dia da colocação do
dispositivo e eCG (200 UI), aplicado na mesma região, 24 h antes de sua
retirada. Os dispositivos permaneceram por seis dias em todos os
tratamentos. Dez cabras de cada tratamento foram avaliadas por
ultrassonografia transretal (5 MHz). Foram efetuadas coletas de sangue
em diferentes momentos para análise de progesterona (P4) plasmática na
estação de anestro estacional. Não houve diferença (P>0,05) entre os três tratamentos nos seguintes parâmetros reprodutivos observados na
estação de anestro e de acasalamento natural, respectivamente (valor
médio dos três tratamentos): taxa média de indução/sincronização de
estro (94,9; 76,2%), intervalo médio da retirada do dispositivo ao estro
(33,1 ± 11,4; 37,4 ± 16,2 h), duração média do estro (28,6 ± 11,8;
31,7 ± 12,8 h), taxa média de concepção (61,5; 50,7%), taxa média de
fêmeas ovulando (95,2; 66,7%), número médio de ovulações (1,7 ± 0,7;1,5 ± 0,6), intervalo médio da retirada do dispositivo à ovulação
(68,4 ± 13,0; 77,3 ± 13,8 h), intervalo médio do início do estro à ovulação
(36,6 ± 12,6; 36,7 ± 11,2 h), diâmetro médio do maior folículo (7,4 ± 0,6;
6,7 ± 0,5 mm), segundo maior (6,8 ± 0,6; 6,2 ± 0,1 mm) e médio
(7,2 ± 0,6; 6,6 ± 0,4 mm). As baixas concentrações iniciais de P4 em
todos os tratamentos sete dias antes da inserção dos dispositivos
(0,12 ± 0,21) ou no momento da inserção (0,23 ± 0,20) podem ser
interpretadas como reflexo da estacionalidade reprodutiva. Às 6 h após a
inserção do dispositivo o tratamento CN apresentou maiores (P<0,05)
concentrações de P4 (7,16 ± 3,64) do que C6 (4,66 ± 2,13) ou C12
(4,34 ± 1,85) e estes valores mantiveram-se superiores até quatro dias
após a inserção. A partir da retirada dos dispositivos, as concentrações
plasmáticas de P4 caíram bruscamente para níveis subluteais. Maiores
concentrações (P<0,05) de P4 plasmáticas foram identificadas em cabras
nulíparas do que em lactantes em diferentes momentos. O processo de
autoclavagem não afetou a eficiência da reutilização de dispositivos
intravaginais de progesterona em parâmetros reprodutivos como taxa de
concepção, indução e sincronização de estro e ovulação em cabras da
raça Toggenburg. Os níveis supraluteais mantidos em todos os
tratamentos durante o período de permanência do dispositivo permitem
inferir que o processo de autoclavagem não interfere na disponibilidade
de progesterona nos dispositivos, constituindo-se em uma alternativa
viável para reduzir os custos dentro de um rebanho caprino. This study aimed to evaluate the efficacy of reusing autoclaved intravaginal devices on induction of estrus, ovulation and fertility in Toggenburg goats, besides to measure the plasma progesterone (P4) profile in these animals. The study was performed during the seasonal anestrous period (n=42) and in the breeding season (n=67), at the City of Piau-MG (latitude 21°35 S and longitude 43°15 W). Goats received new intravaginal progesterone devices (CN), or devices used previously during six days (C6) or 12 days (C12) and then autoclaved. Dinoprost (5 mg) latero-vulvar was administered on the day of device insertion and eCG (200 IU) latero-vulvar was done 24 h before its removal. The devices were maintained for six days in all treatments. Ten goats from each treatment were evaluated by transrectal ultrasonography (5 MHz). Blood was collected at different moments for plasma P4 analysis. There was no statistical difference (P>0.05) among the goats of three treatments on the following reproductive parameters observed during the anestrous or breeding season, respectively (average for three treatments): mean estrous induction/synchronization rate (94.9; 76.2%), mean interval from device removal to estrus (33.1 ± 11.4; 37.4 ± 16.2 h), mean duration of estrus (28.6 ± 11.8; 31.7 ± 12.8 h), mean conception rate (61.5; 50.7%), mean ovulating female rate (95.2; 66.7%), mean number of ovulations (1.7 ± 0.7; 1.5 ± 0.6), mean interval from removal to ovulation (68.4 ± 13.0; 77.3 ± 13.8 h), interval from estrus to ovulation (36.6 ± 12.6; 36.7 ± 11.2 h), mean diameter of the dominant follicle (7.4 ± 0.6; 6.7 ± 0.5 mm), co-dominant (6.8 ± 0.6; 6.2 ± 0.1 mm) and medium (7.2 ± 0.6; 6.6 ± 0.4 mm). The small initial concentrations of P4 in alltreatments seven days before device insertion (0.12 ± 0.21) or at the time of insertion (0.23 ± 0.20) may be interpreted as a consequence of reproductive seasonality. Six hours after device insertion CN treatment showed higher (P<0.05) concentrations of P4 (7.16 ± 3.64) when compared to C6 (4.66 ± 2.13) or to C12 (4.34 ± 1.85) and these values remained greater in size up to four days after insertion. One day after device removal, plasma P4 concentration was at subluteal levels. Higher P4 concentrations (P<0.05) were detected in nulliparous when compared to lactating goats in different moments. The autoclave process did not affect the efficiency of reutilizing progesterone intravaginal device in reproductive parameters as fertility rate, induction and synchronization of estrus and ovulation in Toggenburg goats. The supraluteal concentration maintained in all treatments during the insertion device period allow inferring that the autoclave process does not influence progesterone concentration, being a viable alternative to reduce costs in a goat herd. |
Palavras-chave: | Dispositivos intravaginais Cabras Anestro Contra estação Autoclaved intravaginal Goats Anestrus Estrous Against station |
CNPq: | CNPQ::CIENCIAS AGRARIAS::ZOOTECNIA::PRODUCAO ANIMAL |
Idioma: | por |
País: | BR |
Editor: | Universidade Federal de Viçosa |
Sigla da Instituição: | UFV |
Departamento: | Genética e Melhoramento de Animais Domésticos; Nutrição e Alimentação Animal; Pastagens e Forragicul |
Citação: | SOUZA, Joanna Maria Gonçalves de. Reutilization of autoclaved intravaginal progesterone device for estrous induction and synchronization in Toggenburg goats. 2010. 87 f. Dissertação (Mestrado em Genética e Melhoramento de Animais Domésticos; Nutrição e Alimentação Animal; Pastagens e Forragicul) - Universidade Federal de Viçosa, Viçosa, 2010. |
Tipo de Acesso: | Acesso Aberto |
URI: | http://locus.ufv.br/handle/123456789/5712 |
Data do documento: | 21-Jan-2010 |
Aparece nas coleções: | Zootecnia |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
texto completo.pdf | 391,84 kB | Adobe PDF | Visualizar/Abrir |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.