Use este identificador para citar ou linkar para este item: https://locus.ufv.br//handle/123456789/5062
Tipo: Dissertação
Título: Estudo comparativo entre radiologia convencional e ultrassonografia modo B e Doppler na avaliação de doenças torácicas extracardíacas em cães e gatos
Título(s) alternativo(s): Comparative study between conventional radiology and B-mode and Doppler ultrasonography in the evaluation of non-cardiac thoracic diseases in dogs and cats
Autor(es): Pires, Sâmara Turbay
Primeiro Orientador: Hage, Maria Cristina Ferrarini Nunes Soares
Primeiro coorientador: Costa, Paulo Renato dos Santos
Segundo coorientador: Borges, Andrea Pacheco Batista
Primeiro avaliador: Kodaira, Sérgio Keidi
Segundo avaliador: Hagen, Stefano Carlo Filippo
Terceiro avaliador: Viloria, Marlene Isabel Vargas
Abstract: Este estudo comparou os achados radiográficos e ultrassonográficos modo B e Doppler da cavidade torácica, excluindo o coração, em animais das espécies canina (27) e felina (2), nos casos onde as radiografias torácicas revelaram formação de janela acústica em potencial. O intuito do projeto foi apontar vantagens e limitações de cada uma das técnicas, além de determinar se as informações adicionais tiveram impacto nos diagnósticos diferenciais e nos desfechos. O exame ultrassonográfico modo B apresentou as seguintes vantagens: melhor estimativa da quantidade de efusão pleural, informações qualitativas quanto a sua natureza e identificação de estruturas imersas, além da determinação da natureza sólida ou cística de nódulos, bem como a definição de sua localização no parênquima pulmonar ou em outros compartimentos torácicos. A ultrassonografia Doppler de Amplitude permitiu a avaliação do padrão de irrigação sanguínea de nódulos e massas e a diferenciação entre vasos e broncogramas fluidos. As limitações da técnica ultrassonográfica recaíram na impossibilidade de avaliação do parênquima pulmonar na ausência de janela acústica e, portanto, da necessidade de ser guiada pelo exame radiográfico prévio. As vantagens do exame radiográfico evidenciaram-se na possibilidade de localização de lesões pulmonares em qualquer profundidade na ausência de efusão pleural e principalmente pelo fato de proporcionar uma visão panorâmica da cavidade torácica. As informações obtidaspor meio do exame ultrassonográfico proporcionaram impacto no diagnóstico diferencial de 62,06% dos casos. Em 27,5% dos casos, as informações adicionais influenciaram também o desfecho.
This study compared the radiographic and B-mode and Doppler ultrasonographic findings of the thorax, excluding the heart, of dogs (27) and cats (2) whose thoracic radiographys revealed an potential acoustic window. The aim of this study was to identify advantages and limitations of each technique, besides to determine if these additional informations had impact on differential diagnoses and outcomes. The B-mode ultrasonographic examination showed the following advantages: better estimative of the amount of pleural effusion, qualitative informations regarding its nature, identification of submerged structures, differentiation between solid and cystic nodules, as well as definition of its location in the lung parenchyma or other thoracic compartments. The Power Doppler ultrasonography allowed to assess the blood pattern supply of nodules and masses, and differentiate between vessels and fluid bronchograms. Ultrasonographic limitations were based in the impossibility of evaluation of the lung parenchyma in the absence of an acoustic window and requirement to be guided by previous radiographic examination. The radiographic advantages were the possibility of location of pulmonary lesions in any depth in the absence of pleural effusion and mainly because provided a panoramic view of the thoracic cavity involvement. Informations obtained by the ultrasonographic examination provided impact on the differential diagnosis in 62.06% of the cases. In 27.5% of the cases, additional informations also influenced the outcome.
Palavras-chave: Tórax
Radiologia
Ultrassonografia
Thorax
Radiology
Ultrasonography
CNPq: CNPQ::CIENCIAS AGRARIAS::MEDICINA VETERINARIA::CLINICA E CIRURGIA ANIMAL::RADIOLOGIA DE ANIMAIS
Idioma: por
País: BR
Editor: Universidade Federal de Viçosa
Sigla da Instituição: UFV
Departamento: Biotecnologia, diagnóstico e controle de doenças; Epidemiologia e controle de qualidade de prod. de
Citação: PIRES, Sâmara Turbay. Comparative study between conventional radiology and B-mode and Doppler ultrasonography in the evaluation of non-cardiac thoracic diseases in dogs and cats. 2011. 96 f. Dissertação (Mestrado em Biotecnologia, diagnóstico e controle de doenças; Epidemiologia e controle de qualidade de prod. de) - Universidade Federal de Viçosa, Viçosa, 2011.
Tipo de Acesso: Acesso Aberto
URI: http://locus.ufv.br/handle/123456789/5062
Data do documento: 17-Fev-2011
Aparece nas coleções:Medicina Veterinária

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
texto completo.pdf3,99 MBAdobe PDFThumbnail
Visualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.