Use este identificador para citar ou linkar para este item: https://locus.ufv.br//handle/123456789/3673
Tipo: Dissertação
Título: Análise comparativa entre dois métodos de difusão passiva e ajuste do método Saraz de quantificação de amônia gerada em instalações de produção animal abertas ou híbridas
Título(s) alternativo(s): Comparative analysis of two methods of passive diffusion and adjustment Saraz method of quantification of ammonia generated in animal production facilities opened or hybrid
Autor(es): Sousa, Fernanda Campos de
Primeiro Orientador: Tinôco, Ilda de Fátima Ferreira
Primeiro coorientador: Saraz, Jairo Alexander Osorio
Segundo coorientador: Paula, Marcos Oliveira de
Primeiro avaliador: Albino, Luiz Fernando Teixeira
Segundo avaliador: Souza, Cecília de Fátima
Abstract: Objetivou-se, com esse estudo, analisar comparativamente dois métodos de fluxo passivo, Saraz e Ferm Tube, para determinação da concentração e taxas de emissão de amônia, em instalações predominantemente abertas, ou híbridas, comumente adotadas em países de climas tropicais e subtropicais, como é o caso do Brasil e de países da América do Sul, bem como o ajuste do método Saraz, pelo desenvolvimento de uma equação de ajuste. A análise comparativa entre os métodos foi realizada com base em revisão de literatura por resultados de pesquisas já existentes, que tratavam de diversas metodologias para quantificação de amônia, em termos dos requisitos: aplicabilidade, custo, eficiência e uso do referido método em condições de campo. O ajuste do método Saraz foi resultado do desenvolvimento de equações de ajuste para medição de concentração e taxa de emissão de amônia em ambientes com diferentes características de concentração do gás e velocidade do ar de exaustão. Para isso foi desenvolvida uma caixa balizadora, dividida em setores; de entrada e saída de gás, sendo que, entre estes ficavam posicionados exaustores e materiais porosos absorventes para fixação da amônia. Por meio da mistura de gases, foram obtidas diferentes concentrações de amônia, monitoradas por sensores, associadas a diferentes velocidades do ar de exaustão. O experimento foi realizado em câmara climática com controle e monitoramento da temperatura e umidade do ar. Diante das análises comparativas realizadas entre os métodos Ferm Tube e Saraz, foi possível observar que, no geral, em condições de ventilação natural, nos galpões abertos, ou híbridos, o método Saraz mostrou-se mais apropriado que o Ferm Tube. No ajuste do método Saraz, além da obtenção da equação de ajuste, foi possível observar que, em velocidades do ar de até 2,4 m.s -1 e em concentrações de amônia de até 25 ppm, o método pode ser usado com confiabilidade, mas, como ocorre com outros métodos, à medida em que ocorre aumento de velocidade do ar e de concentração, sua eficiência diminui.
The objective, of this study, was to comparatively analyze two methods of passive flow, Saraz and Ferm Tube, to determine the concentrations and emission rates of ammonia in predominantly open or hybrid facilities, commonly adopted in countries of tropical and subtropical climates, as is the case of Brazil and countries in South America as well as the adjustment of Saraz method for developing an adjustment equation. The comparative analysis between the methods was conducted based on literature review results by existing research, which dealt with various methodologies for quantification of ammonia in terms of requirements: applicability, cost, efficiency and use of the method in field conditions. The adjustment of Saraz method, was the result of the development of equations to adjust for measurement of concentration and rate of ammonia emission in environments with different characteristics of the gas concentration and velocity of the exhaust air. To this a box comprising three compartments, divided into sectors been developed; input and output gas, and that between these compartments positioned hoods were porous and absorbent material for fixation of ammonia. By means of the gas mixture, different concentrations of ammonia monitored by sensors associated to different speeds of the exhaust air were obtained. The experiment was conducted in climatic chambers with control and monitoring of temperature and humidity of air. Given the comparative analyzes between methods Ferm Tube and Saraz, it was observed that, in general, under conditions of natural ventilation in the open, or hybrid facilities, the Saraz method was more appropriate than Ferm Tube. In setting Saraz method, in addition to obtaining the adjustment equation, we observed that in air velocities up to 2.4 m.s -1 and ammonia concentrations of up to 25 ppm, the method can be used reliably but, as with other methods, to the extent that increasing air velocity and concentration occurs, its efficiency decreases.
Palavras-chave: Amônia - Concentração
Poluição do ar
Método Saraz
Engenharia agrícola - Inovações
Ammonia - Concentration
Air pollution
Saraz method
Agricultural engineering - Innovations
CNPq: CNPQ::CIENCIAS AGRARIAS::ENGENHARIA AGRICOLA::CONSTRUCOES RURAIS E AMBIENCIA
Idioma: por
País: BR
Editor: Universidade Federal de Viçosa
Sigla da Instituição: UFV
Departamento: Construções rurais e ambiência; Energia na agricultura; Mecanização agrícola; Processamento de produ
Citação: SOUSA, Fernanda Campos de. Comparative analysis of two methods of passive diffusion and adjustment Saraz method of quantification of ammonia generated in animal production facilities opened or hybrid. 2014. 55 f. Dissertação (Mestrado em Construções rurais e ambiência; Energia na agricultura; Mecanização agrícola; Processamento de produ) - Universidade Federal de Viçosa, Viçosa, 2014.
Tipo de Acesso: Acesso Aberto
URI: http://locus.ufv.br/handle/123456789/3673
Data do documento: 19-Fev-2014
Aparece nas coleções:Engenharia Agrícola

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
texto completo.pdf351,23 kBAdobe PDFThumbnail
Visualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.