Use este identificador para citar ou linkar para este item: https://locus.ufv.br//handle/123456789/22072
Tipo: Artigo
Título: Comparison of univariate and multivariate magnitude-squared coherences in the detection of human 40-Hz auditory steady-state evoked responses
Autor(es): Felix, Leonardo Bonato
Antunes, Felipe
Carvalho, Jean Antônio da Silva
Barroso, Márcio Falcão dos Santos
Sá, Antonio Mauricio Ferreira Leite Miranda de
Abstract: Objective response detection (ORD) techniques for evaluating bioelectrical evoked responses in the electroencephalogram (EEG) are based on statistical criteria rather than on visual inspection. Hence, they do not depend on human evaluation, which is often a subjective approach. Furthermore, since such techniques do not involve heuristic approaches, they may be more easily implemented and used in automatic systems. The Magnitude-Squared Coherence (MSC), together with its recently developed multivariate extension (the multiple magnitude-squared coherence – MMSC), have been pointed out as one of the most efficient ORD techniques for detecting steady-state responses in the EEG. In this work, both MSC and MMSC were applied to EEG signals collected during auditory stimulation in order to allow comparison in the detection of auditory steady-state responses (ASSRs). The stimuli consisted of 40 Hz amplitude-modulated tones delivered binaurally in the intensity of 50 dB SPL (sound pressure level). The best result was obtained by using MMSC in the two-electrode set C4 and Fz. This configuration led to a 0.92-detection ratio, within 111.55 s in average to detect each response and kept the false alarm ratio under 0.05. The average improvement in performance was about 11% when compared to the MSC. These results allow concluding that the detection protocol of 40 Hz ASSRs can be improved by using MMSC in multichannel EEG analysis when compared to the traditional univariate MSC approach.
Palavras-chave: Auditory steady-state responses
Magnitude-squared coherence
Multiple magnitude-squared coherence
Electroencephalogram
Editor: Biomedical Signal Processing and Control
Tipo de Acesso: Elsevier Ltd.
URI: https://doi.org/10.1016/j.bspc.2017.09.024
http://www.locus.ufv.br/handle/123456789/22072
Data do documento: Fev-2018
Aparece nas coleções:Artigos

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
artigo.pdf
  Until 2100-12-31
texto completo632,57 kBAdobe PDFVisualizar/Abrir ACESSO RESTRITO


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.